Every batch we sell is tested by an independent laboratory: ILS Laboratories in San Diego or Janoshik Analytical in the Czech Republic. This page lists 2026 results for batches currently on sale, each with a link to verify the report on the laboratory's own website.
How to verify a Janoshik or ILS report ↓
Is every Panda Peptides batch third-party tested?
Yes. Each batch below was tested in 2026 by ILS Laboratories or Janoshik Analytical, neither of which is owned by Panda or paid according to the result. Purity is the lab’s HPLC result; where the lab tested several vials from the same batch, the average of all vials is shown underneath. Measured content is the amount of material the lab found in the vial, compared with the amount on the label.
2026 purity chart
HPLC purity for the 51 batches whose report gives one, highest first. The bars start at 95% so that small differences show. The other 4 batches have reports that give an amount but no HPLC purity; they are in the table below.
Every batch on sale, with its lab results
| Product | Batch | Tested | Purity (HPLC) | Measured content | Other tests | Report |
|---|---|---|---|---|---|---|
| PP2603-001B | Janoshik AnalyticalJul 28, 2026 | — | 40.29mg101% of the 40mg label | Endotoxin: <10 EU/Vial | Verify #212696 ↗ View report All reports | |
| PP2605-056 | ILS LaboratoriesOct 9, 2026 | 99.27%average of 3 vials 99.31% | 10.2mg102% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-FNLBGE ↗ View report All reports | |
| PP2607-003A | ILS LaboratoriesNov 7, 2026 | 99.90%average of 3 vials 99.53% | 5.12mg102% of the 5mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-C4KC_F ↗ View report All reports | |
| PP2605-042 | ILS LaboratoriesOct 9, 2026 | 99.73%average of 3 vials 99.78% | 10.72mg107% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-HQGXKJ ↗ View report All reports | |
| PP2605-004 | ILS LaboratoriesOct 9, 2026 | 99.09%average of 3 vials 98.91% | 10.64mg106% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-JN5DV- ↗ View report All reports | |
| PP2605-006A | ILS LaboratoriesSep 16, 2026 | 99.82%average of 3 vials 99.81% | 5.35mg107% of the 5mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-2VS-SR ↗ View report All reports | |
| PP2605-006B | ILS LaboratoriesSep 16, 2026 | 99.75%average of 3 vials 99.76% | 10.26mg103% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-DAHQ9G ↗ View report All reports | |
| PP2602-007A | Janoshik AnalyticalMay 4, 2026 | — | BPC-157 5.61mg112% of the 5mg on the labelTB-500 5.69mg114% of the 5mg on the label | — | Verify #152434 ↗ View report All reports | |
| PP2605-007B | ILS LaboratoriesSep 16, 2026 | 99.77%average of 3 vials 99.79% | BPC-157 10.83mg108% of the 10mg on the labelTB-500 10.4mg104% of the 10mg on the labelAmounts per peptide from the lab’s dedicated vial | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-BPLUKU ↗ View report All reports | |
| PP2605-051 | ILS LaboratoriesOct 9, 2026 | 99.77%average of 3 vials 99.74% | 21.21mg106% of the 20mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-NXVDGH ↗ View report All reports | |
| PP2605-008 | ILS LaboratoriesSep 16, 2026 | 99.52%average of 3 vials 99.35% | CJC-1295 5.05mg101% of the 5mg on the labelIpamorelin 5.26mg105% of the 5mg on the labelAmounts per peptide from the lab’s dedicated vial | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026–D_Y5P ↗ View report All reports | |
| PP2605-043 | ILS LaboratoriesSep 16, 2026 | 98.27%average of 3 vials 98.33% | 5.16mg103% of the 5mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-IWIIVY ↗ View report All reports | |
| PP2606-017H | ILS LaboratoriesOct 20, 2026 | 98.89%average of 3 vials 99% | 62.16mg104% of the 60mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-JGINNO ↗ View report All reports | |
| PP2603-010B | Janoshik AnalyticalJul 30, 2026 | 99.26% | 10mg100% of the 10mg label | Endotoxin: <10 EU/Vial | Verify #212684 ↗ View report All reports | |
| PP2602-012AA | Janoshik AnalyticalJun 1, 2026 | 99.92% | 47.28mg95% of the 50mg label | — | Verify #168135 ↗ View report All reports | |
| PP2602-012AB | Janoshik AnalyticalJun 1, 2026 | 99.79% | 54.14mg108% of the 50mg label | — | Verify #168141 ↗ View report All reports | |
| PP2605-012B | ILS LaboratoriesSep 16, 2026 | 98.34%average of 3 vials 99.22% | 103.64mg104% of the 100mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-1DHS3E ↗ View report All reports | |
| PP2605-013 | ILS LaboratoriesSep 16, 2026 | 99.65%average of 3 vials 99.63% | GHK-Cu 52.99mg106% of the 50mg on the labelBPC-157 10.45mg104% of the 10mg on the labelTB-500 10.16mg102% of the 10mg on the labelAmounts per peptide from the lab’s dedicated vial | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-00SCUG ↗ View report All reports | |
| PP2605-016B | ILS LaboratoriesSep 16, 2026 | 99.23%average of 3 vials 98.95% | 10.63mg106% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-827RPA ↗ View report All reports | |
| PP2605-019B | Janoshik AnalyticalSep 16, 2026 | 98.72%average of 3 vials | 1,491.86mg99% of the 1,500mg label | Endotoxin: <1 EU/vial · Heavy metals: Not detected · Sterility (TAMC/TYMC): Pass | Verify #231308 ↗ View report All reports | |
| PP2605-020 | Janoshik AnalyticalSep 14, 2026 | — | 5,417 IU108% of the 5,000 IU label | Heavy metals: Not detected · Sterility (TAMC/TYMC): Pass | Verify #231328 ↗ View report All reports | |
| PP2604-023A | ILS LaboratoriesAug 18, 2026 | 99.66%average of 2 vials 99.13% | 1.05mg105% of the 1mg label | Identity confirmed · Endotoxin 0.076 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-RTH9MC ↗ View report All reports | |
| PP2605-024B | ILS LaboratoriesSep 16, 2026 | 99.82%average of 3 vials 98.88% | 10.48mg105% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-M5Q–Q ↗ View report All reports | |
| PP2605-025A | ILS LaboratoriesSep 16, 2026 | 98.55%average of 3 vials 98.79% | 5.23mg105% of the 5mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-L5WUXB ↗ View report All reports | |
| PP2607-027 | ILS LaboratoriesNov 7, 2026 | 99.65%average of 3 vials 99.18% | 10.42mg104% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-OLJCJH ↗ View report All reports | |
| PP2603-028 | Janoshik AnalyticalJul 31, 2026 | — | 668mg111% of the 600mg label66.80 mg/mL total solids × 10 mL | — | Verify #212700 ↗ View report All reports | |
| PP2605-030 | ILS LaboratoriesSep 16, 2026 | 99.62%average of 3 vials 99.65% | 10.62mg106% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-3EUTNN ↗ View report All reports | |
| PP2605-031A | ILS LaboratoriesSep 16, 2026 | 99.62%average of 3 vials 99.65% | 10.44mg104% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-C96L0G ↗ View report All reports | |
| PP2607-031C | ILS LaboratoriesNov 7, 2026 | 99.69%average of 3 vials 99.50% | 21.17mg106% of the 20mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-EVKNLU ↗ View report All reports | |
| PP2606-031B | ILS LaboratoriesOct 20, 2026 | 99.71%average of 3 vials 99.38% | 42.24mg106% of the 40mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-UJVL_M ↗ View report All reports | |
| PP2604-048 | ILS LaboratoriesAug 19, 2026 | 99.89%average of 2 vials 99.87% | 10.47mg105% of the 10mg label | Identity confirmed · Endotoxin 0.076 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-CELKDV ↗ View report All reports | |
| PP2606-032 | ILS LaboratoriesOct 27, 2026 | 99.62%average of 3 vials 99.47% | 528.04mg106% of the 500mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-8ZAOCW ↗ View report All reports | |
| PP2607-054A | ILS LaboratoriesNov 7, 2026 | 99.46%average of 3 vials 99.31% | 10.49mg105% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-7Q_7WC ↗ View report All reports | |
| PP2607-054C | ILS LaboratoriesNov 7, 2026 | 99.84%average of 3 vials 99.77% | 52.6mg105% of the 50mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-DFQI9B ↗ View report All reports | |
| PP2605-059 | ILS LaboratoriesOct 12, 2026 | 98.57%average of 3 vials 98.20% | 10.26mg103% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-XIFWZZ ↗ View report All reports | |
| PP2605-014B | ILS LaboratoriesSep 16, 2026 | 99.61%average of 3 vials 99.30% | 10.61mg106% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-PP-B0I ↗ View report All reports | |
| PP2604-039B | ILS LaboratoriesAug 18, 2026 | 99.48%average of 2 vials 99.49% | 10.49mg105% of the 10mg label | Identity confirmed · Endotoxin 0.076 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-V0BGGG ↗ View report All reports | |
| PP2606-055 | ILS LaboratoriesOct 20, 2026 | 99.90%average of 3 vials 99.68% | PP-Tesa 10.4mg104% of the 10mg on the labelIpamorelin 3.18mg106% of the 3mg on the labelAmounts per peptide from the lab’s dedicated vial | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-G6MOGC ↗ View report All reports | |
| PP2605-034 | ILS LaboratoriesSep 16, 2026 | 99.83%average of 3 vials 99.20% | 10.51mg105% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-2KA6_T ↗ View report All reports | |
| PP2605-035B | ILS LaboratoriesSep 16, 2026 | 99.58%average of 3 vials 99.59% | 10.42mg104% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-A9JGM_ ↗ View report All reports | |
| PP2605-036B | ILS LaboratoriesSep 16, 2026 | 99.36%average of 3 vials 98.85% | 10.36mg104% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-PZDR2O ↗ View report All reports | |
| PP2605-037 | ILS LaboratoriesSep 16, 2026 | 98.96%average of 3 vials 99.13% | 10.61mg106% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-4B87E- ↗ View report All reports | |
| PP2605-049 | ILS LaboratoriesOct 9, 2026 | 99.54%average of 3 vials 99.51% | 10.25mg102% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-TVBQIX ↗ View report All reports | |
| PP2605-038B | ILS LaboratoriesOct 19, 2026 | 99.45%average of 3 vials 99.55% | 10.47mg105% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-9KMDBW ↗ View report All reports | |
| PP2602-041A | Janoshik AnalyticalJun 1, 2026 | 99.35% | 5.7mg114% of the 5mg label | Endotoxin: 2.483 EU/Vial | Verify #168162 ↗ View report All reports | |
| PP2605-041B | ILS LaboratoriesSep 16, 2026 | 99.70%average of 3 vials 99.29% | 10.26mg103% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-OVL21G ↗ View report All reports | |
| PP2605-018A | ILS LaboratoriesSep 16, 2026 | 99.90%average of 3 vials 98.30% | 5.19mg104% of the 5mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals pass · Fentanyl screen: not detected | Verify COA-2026-GGMSGI ↗ View report All reports | |
| PP2605-018B | ILS LaboratoriesOct 9, 2026 | 99.76%average of 3 vials 99.20% | 10.69mg107% of the 10mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-3IFIPN ↗ View report All reports | |
| PP2606-018C | ILS LaboratoriesOct 20, 2026 | 99.91%average of 3 vials 99.09% | 15.72mg105% of the 15mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-IJJ3YF ↗ View report All reports | |
| PP2607-018D | ILS LaboratoriesNov 11, 2026 | 99.61%average of 3 vials 99.61% | 21.33mg107% of the 20mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-HLUZQO ↗ View report All reports | |
| PP2606-018D | ILS LaboratoriesOct 20, 2026 | 99.90%average of 3 vials 99.78% | 21.17mg106% of the 20mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-V0VFPI ↗ View report All reports | |
| PP2605-018D | Janoshik AnalyticalSep 15, 2026 | 99.93%average of 3 vials | 21.69mg108% of the 20mg label | Identity confirmed (blind test) · Endotoxin: <1 EU/vial · Heavy metals: Not detected · Sterility (TAMC/TYMC): Pass | Verify #231320 ↗ View report All reports | |
| PP2605-018E | Janoshik AnalyticalSep 15, 2026 | 99.82%average of 3 vials | 32.97mg110% of the 30mg label | Identity confirmed (blind test) · Endotoxin: <1 EU/vial · Heavy metals: Not detected · Sterility (TAMC/TYMC): Pass | Verify #231316 ↗ View report All reports | |
| PP2606-018F | ILS LaboratoriesOct 20, 2026 | 99.84%average of 3 vials 98.99% | 42.64mg107% of the 40mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-EBYJ2I ↗ View report All reports | |
| PP2606-018G | ILS LaboratoriesOct 20, 2026 | 99.34%average of 3 vials 99.65% | 52.59mg105% of the 50mg label | Identity confirmed · Endotoxin ≤ 0.05 EU/mL · Sterility: no growth · Heavy metals not detected · Fentanyl screen: not detected | Verify COA-2026-NJLBUX ↗ View report All reports |
Results describe the samples each laboratory tested from the batch shown. Each product’s report page (All reports) also keeps its earlier batches. All products are sold for laboratory research use only.
Can I share or cite these results?
Yes. The results on this page, the table and the CSV, are free to reuse under the Creative Commons Attribution 4.0 license, including on other websites and in research. Please credit Panda Peptides and link to this page.
Cite as: Panda Peptides, 2026 third-party lab results, https://pandapeptides.com/coa/
Janoshik reports explained: how to verify one and what each test shows
A Janoshik report is a test certificate from Janoshik Analytical, an independent laboratory in the Czech Republic that tests samples sent in by vendors and buyers. Every report has a matching record on Janoshik’s own website, so you never have to rely on a screenshot.
How to verify a Janoshik report in 3 steps
- Find the task number and the key. The task number is at the top of the report (for example #231316). The unique key is printed at the bottom, after “Verify this test at www.janoshik.com/verify/”.
- Open the record on Janoshik’s website. Enter both on Janoshik’s verification page, or use the Verify link next to any report on this page, which opens the record directly.
- Compare it line by line. The task number, sample, batch, results and dates should match the copy you were given exactly. If anything differs, the record on Janoshik’s website is the one that counts.
ILS Laboratories reports work the same way: each one carries an access code and a QR code that open the record on the ILS portal.
What each Janoshik test shows
| Test | What it tells you | Example from our reports |
|---|---|---|
| HPLC purity | The share of the material the lab detected that is the target compound. It does not tell you how much is in the vial. | GHK-Cu 50mg, batch PP2602-012AA: 99.925% (#168135) |
| Amount | How many milligrams of the compound the lab measured in the vial, to compare with the label. | The same vial held 47.28mg against a 50mg label (94.6%). A second batch, PP2602-012AB, measured 54.14mg (108.3%, #168141). |
| Identity (blind test) | The vial goes in under a neutral name such as “Sample 3”, and the lab has to identify the compound itself rather than confirm a name it was given. | Triple Receptor Agonist 30mg, batch PP2605-018E: identity confirmed, with 99.817% mean purity and 32.97mg mean content across three vials (#231316) |
| Endotoxin | Bacterial endotoxin in the vial, in endotoxin units (EU). Lower is better. | The same Triple Receptor Agonist 30mg batch: less than 1 EU per vial (#231317) |
| Heavy metals | A screen for arsenic, cadmium, lead and mercury. “Not detected” means below the method’s detection limit. | HCG 5000IU, batch PP2605-020: none of the four detected (#231330) |
| Sterility (TAMC/TYMC) | Culture tests for aerobic bacteria (TAMC) and for yeasts and moulds (TYMC), each reported as a pass or a fail. | Glutathione 1500mg, batch PP2605-019B: both passed (#231311) |
What a Janoshik report doesn’t prove
- It covers the sample that was tested. Check that the batch on the report, or the batch we list beside it, matches the batch on your vial.
- Purity is not amount. A vial can test 99.9% pure and still hold less than the label says, so read both numbers.
- One batch doesn’t cover another. A report on one size or batch says nothing about a different one.
- A screenshot is not a record. Images can be edited; the record on Janoshik’s website is the reference.
Which laboratories test Panda products?
ILS Laboratories (San Diego, California) runs our full-panel tests: identity, HPLC purity and content across two or three vials per batch, plus endotoxin, sterility, heavy metals and a fentanyl screen. Janoshik Analytical (Czech Republic) tests purity and content, with separate endotoxin, sterility and heavy-metal reports for some batches. Read why we use both labs.
COAs, testing standards, and research documentation
Use this COA directory with our Quality & Testing standards, laboratory-selection guide, research evaluation guide, and FAQ. These resources explain documentation and analytical verification only; they do not provide protocol, dosing, administration, treatment, or human-use guidance.
- How to read a peptide COA: purity, amount and batch verification
- Compare before you buy: a peptide vendor checklist
Read the report, not just the headline